Evaluation of health, environmental, economic and technical aspects of disinfection of WWTP effluent in the north of Isfahan with UV instead of chlorine
Hasan Hashemi 1, Mohammad Mehdi Amin Dr 2, Asghar Ebrahimi 3, Reza Rezaie 4, Mehdi Safari 4
1- Instructor Shahrekord University of Medical Sciences
2- Assistant professor Isfahan University of Medical Sciences , amin@hlth.mui.ac.ir
3- Yazd University of Medical Sciences
4- Instructor Sanandaj University of Medical Sciences
Abstract:  
ABSTRACT Background and aim: Today, chlorine is the most common material used for effluent disinfection. Chlorination is an established and effective method for effluent disinfection. But the use of chlorine for disinfection of effluent due to several major concerns should be reassessed. The aim of this study was to compare long-term benefits and costs of chlorination/de chlorination with those of UV by pilot studies. Material and Methods: This pilot study consisted of pre-treatment units clarification and filtration systems with two types of low pressure and medium pressure UV lamps designed and installed at the wastewater treatment plant in the north of Isfahan. Results:Medium pressure UV systems with dose of 230 mw.s/cm2 for disinfection of filtered effluent with SOR of 1090 lit/m2.hr is more economical than a low pressure system and chlorination/dechlorination process and has the least environmental and health adverse effects. Conclusion: In wastewater treatment plants use of UV disinfection technology should be considered in preference to chlorination, especially if the dechlorination of chlorinated effluent is required. Before application of this system pilot studies on actual effluent at plant sites are required. Keywords: Effluent disinfection, UV radiation, Chlorination, pilot study Received: Oct 3, 2010 Accepted: Nov 5, 2011 Conflict of interest: Nill
Keywords: Effluent disinfection, UV radiation, Chlorination, pilot study
Full-Text [PDF 673 kb]      
Type of Study: Research | Subject: General
Received: 2011/12/3
Send email to the article author

Add your comments about this article
Your username or Email:

Write the security code in the box >


XML   Persian Abstract   Print



Volume 16, Issue 4 (Scientific Journal of Kurdistan University of Medical Sciences 2012) Back to browse issues page
مجله علمی دانشگاه علوم پزشکی کردستان Scientific Journal of Kurdistan University of Medical Sciences
مجله علمی دانشگاه علوم پزشکی کردستان Scientific Journal of Kurdistan University of Medical Sciences
Persian site map - English site map - Created in 0.07 seconds with 30 queries by YEKTAWEB 3667