<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Scientific Journal of Kurdistan University of Medical Sciences</title>
<title_fa>مجله علمي دانشگاه علوم پزشكي كردستان</title_fa>
<short_title>SJKU</short_title>
<subject>General</subject>
<web_url>http://sjku.muk.ac.ir</web_url>
<journal_hbi_system_id>54</journal_hbi_system_id>
<journal_hbi_system_user>journal54</journal_hbi_system_user>
<journal_id_issn>1560-652X</journal_id_issn>
<journal_id_issn_online>2345-4040</journal_id_issn_online>
<journal_id_pii>sjku</journal_id_pii>
<journal_id_doi>10.61186/sjku</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1399</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2020</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<volume>25</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی حدت بینایی و عیوب انکساری باقیمانده پس از عمل جراحی بیماران با آب مروارید وابسته به سن به روش فیکوامولسیفیکشن</title_fa>
	<title>Investigation of visual acuity and residual refractive error after cataract surgery in patients with senile cataract by phacoemulsification</title>
	<subject_fa>عمومى</subject_fa>
	<subject>General</subject>
	<content_type_fa>پژوهشي اصیل</content_type_fa>
	<content_type>Original Research</content_type>
	<abstract_fa>&lt;strong&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;زمینه و هدف: &lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;بهبود دید و کاهش عیوب انکساری از اهداف مهم عمل جراحی آب مروارید محسوب می&#8204;شود. هدف از این مطالعه بررسی حدت بینایی و عیوب انکساری باقیمانده پس از عمل جراحی در بیماران با آب مروارید وابسته به سن مراجعه&amp;shy;کننده به بیمارستان شهید رحیمی خرم&#8204;آباد در سال 97-1396 است.&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;مواد و روش &amp;shy;ها: &lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;در این مطالعه مقطعی علاوه بر عیوب انکساری، حدت بینایی و بیومتری 192 چشم (از 176 بیمار) مبتلا به آب مروارید وابسته به سن قبل و یک ماه بعد ازعمل جراحی بررسی شد. اندازه&#8204;گیری عیب انکساری با اتورفرکتومتر، بیومتری توسط دستگاه &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-family:Times New Roman,serif;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;IOL Master&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;و محاسبه قدرت لنز داخل چشمی با فرمول &lt;/span&gt;&lt;/span&gt;&amp;nbsp;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-family:Times New Roman,serif;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;SRK/T&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;انجام گرفت. جهت انجام تحلیل آماری در صورت توزیع نرمال داده&#8204;ها از آزمون تی تست زوجی و در غیر این صورت از تست ناپارامتری ویلکاکسون استفاده شد و سطح معنی&#8204;داری آزمون کمتر از&lt;/span&gt;&lt;/span&gt; &lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;05/0 در نظر گرفته شد.&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;یافته&amp;shy; ها: &lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;از 192 چشم مورد مطالعه، میانگین اکی&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-family:Times New Roman,serif;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;&amp;shy;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;والان&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-family:Times New Roman,serif;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;&amp;shy;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;اسفر بیماران قبل از عمل 0/22&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:Times New Roman,serif;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;&amp;plusmn;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt; 0/7- دیوپتر بود که بعد از عمل به 0/06&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:Times New Roman,serif;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;&amp;plusmn;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;0/04- دیوپتر رسید (0/001&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-family:Times New Roman,serif;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;P&lt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;). میانگین حدت بینایی با بهترین اصلاح اپتیکی قبل از عمل 0/01&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:Times New Roman,serif;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;&amp;plusmn;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;0/42 بود که به 0/01&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:Times New Roman,serif;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;&amp;plusmn;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;0/91 بعد از عمل تغییر یافت (0/0001&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-family:Times New Roman,serif;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;P&lt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;). میانگین طول محوری چشم&#8204;ها قبل از عمل0/05&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:Times New Roman,serif;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;&amp;plusmn;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;23/13 میلی&amp;shy;&#8204;متر بود که به 0/05&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:Times New Roman,serif;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;&amp;plusmn;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt; 23/07 میلی&amp;shy;&#8204;متر بعد از عمل رسید (0/001&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-family:Times New Roman,serif;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;P&lt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;) و میانگین عمق اتاق قدامی قبل از عمل&lt;/span&gt;&lt;/span&gt; &lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;از 0/02&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:Times New Roman,serif;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;&amp;plusmn;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;3/07 به 0/03&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:Times New Roman,serif;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;&amp;plusmn;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;3/73 میلی&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-family:Times New Roman,serif;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;&amp;shy;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;متر بعد از عمل افزایش یافت (0/0001&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-family:Times New Roman,serif;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;P&lt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;).&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;strong&gt;&lt;span dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;نتیجه&#8204;گیری:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;span dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt; یافته&#8204;ها نشان می&#8204;دهد که عیوب انکساری در بیش از 86 درصد از بیماران مورد مطالعه بعد از عمل در محدوده قابل قبول (معادل اسفر 1/00&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family:Times New Roman,serif;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;&amp;plusmn; &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family:B Zar;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;دیوپتر) است و حدت بینایی بعد از عمل در تمام بیماران با بهترین اصلاح اپتیکی 0/5 یا بهتر بود.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&amp;nbsp;</abstract_fa>
	<abstract>&lt;strong&gt;Background and Aim:&lt;/strong&gt; Vision improvement and reduction of refractive errors are considered as important goals of cataract surgery. The purpose of this study was to evaluate residual refractive errors after cataract surgery in the patients with senile cataract in Shahid Rahimi Hospital in Khorramabad City between 2017 and 2018.&lt;br&gt;
&lt;strong&gt;Material and Methods&lt;/strong&gt;: This cross-sectional study included 178 patients. Visual acuity, refractive errors and biometry of 192 eyes with senile cataract were evaluated before and one month after surgery. Refractive error and biometry measurements were performed with an autorefractometer and IOL master, respectively. SRK/T formula was used for IOL power calculation. We used paired T-test for analysis of data with normal distribution and non-parametric Wilcoxon test for the rest of data. P&lt;0.05 was considered statistically significant.&lt;br&gt;
&lt;strong&gt;Results&lt;/strong&gt;: The mean equivalent spherical refraction decreased from -0.7 &amp;plusmn;0.22 before surgery to -0.04 &amp;plusmn;0.06 after surgery (P&amp;le;0.001). Before and after surgery ,the mean values for corrected visual acuity were 0.42&amp;plusmn;0.01 D and 0.91&amp;plusmn;0.01 D (P&amp;le;0.0001) and the mean values for axial length of the eyes were 23.13&amp;plusmn;0.05 and 23.07&amp;plusmn;0.05, respectively (P&amp;le;0.001). The mean values for anterior chamber depth of the eyes was 3.07&amp;plusmn;0.02 mm before the surgery which changed to 3.73 &amp;plusmn;0.03 mm after the surgery (P&amp;le;0.0001).&amp;nbsp;&amp;nbsp;&lt;br&gt;
&lt;strong&gt;Conclusion&lt;/strong&gt;: The results showed that refractive errors (%86) after cataract surgery were within acceptable range (&amp;plusmn;1.00 D) and the best corrected visual acuity was better than 0.5</abstract>
	<keyword_fa>حدت بینایی, جراحی کاتاراکت, عیب انکساری, بیومتری, فیکوامولسیفیکشن</keyword_fa>
	<keyword>Visual acuity, Cataract surgery, Refractive error</keyword>
	<start_page>23</start_page>
	<end_page>30</end_page>
	<web_url>http://sjku.muk.ac.ir/browse.php?a_code=A-10-4556-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Saeed</first_name>
	<middle_name></middle_name>
	<last_name>Rahmani</last_name>
	<suffix></suffix>
	<first_name_fa>سعید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رحمنی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>medicalopto@yahoo.com</email>
	<code>5400319475328460035290</code>
	<orcid>5400319475328460035290</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Optometry, School of Rehabilitation, Shahid Beheshti University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>گروه اپتومتری، دانشکده علوم توانبخشی، دانشگاه علوم پزشکی شهید بهشتی، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Atefeh</first_name>
	<middle_name></middle_name>
	<last_name>Farashi Beyramvand</last_name>
	<suffix></suffix>
	<first_name_fa>عاطفه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فراشی بیراموند</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>atefeh.farashi1369@gmail.com</email>
	<code>5400319475328460035291</code>
	<orcid>5400319475328460035291</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>School of Rehabilitation, Shahid Beheshti University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>دانشکده علوم توانبخشی، دانشگاه علوم پزشکی شهید بهشتی، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Seyyed Hadi</first_name>
	<middle_name></middle_name>
	<last_name>Ali</last_name>
	<suffix></suffix>
	<first_name_fa>هادی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>علی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>5400319475328460035292</code>
	<orcid>5400319475328460035292</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Ophthalmologist, Shahid Rahimi Hospital, Khorramabad, Iran</affiliation>
	<affiliation_fa>بیمارستان شهید رحیمی خرم‌آباد، دانشگاه علوم پزشکی لرستان، لرستان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Alireza</first_name>
	<middle_name></middle_name>
	<last_name>Akbarzadeh Baghban</last_name>
	<suffix></suffix>
	<first_name_fa>علیرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>اکبرزاده باغبان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>akbarzad@sbmu.aci</email>
	<code>5400319475328460035293</code>
	<orcid>5400319475328460035293</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Proteomics Research Center, Department of Biostatistics, School of Allied Medical Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>مرکز تحقیقات پروتئومیکس، گروه آمار زیستی، دانشکده علوم پیراپزشکی، دانشگاه علوم پزشکی شهید بهشتی،تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Haleh</first_name>
	<middle_name></middle_name>
	<last_name>Kangari</last_name>
	<suffix></suffix>
	<first_name_fa>هاله</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کنگری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>hkangari@sbmu.acir</email>
	<code>5400319475328460035294</code>
	<orcid>5400319475328460035294</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Optometry, School of Rehabilitation, Shahid Beheshti University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>گروه اپتومتری، دانشکده علوم توانبخشی، دانشگاه علوم پزشکی شهیدبهشتی، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
